Fouten Fouten Fouten
15961836110
Electric corrosion-resistant ball valve Q941F-10P

Electric corrosion-resistant ball valve Q941F-10P

Product Features
Corrosion resistant, remote switch, flange connection
Model number
Q941F-10P
Specification and caliber
DN15-DN200
Pressure level
PN10/PN16
Material
PPH or UPVC
Product Introduction

Electric corrosion-resistant ball valve Q941F-10P Product Description

The electric corrosion-resistant ball valve Q941F-10P is suitable for automatic switching, switching or process control in electroplating, environmental protection, chemical wastewater and water treatment systems. Before determining the configuration, a comprehensive judgment should be made based on the composition of the medium, operating temperature, maximum and normal flow rates, pressure before and after the valve, connection standards, operating frequency, and control signals. The model cannot be directly determined based solely on the existing pipe diameter. The following parameters are commonly used configuration ranges, and actual supply should be based on project conditions, technical confirmation forms, and manufacturing drawings.

Product Specifications

Product ModelQ941F-10P
Structural formTwo piece straight channel, flange connection, floating ball structure
Nominal DiameterDN15-DN200
pressure ratingPN10/PN16
Valve body materialPPH or UPVC
sealing formPTFE Soft Seal
Drive TypeAngular stroke electric actuator
Applicable temperature-10℃ to 90℃, confirm according to the valve body material
Applicable MediumSalt solutions, weak acid bases, and compatible chemical media

Structure and working mode

Q941F-10P adopts a two-piece straight channel, flange connection, and floating ball structure. During operation, the angle stroke electric actuator drives the opening and closing components to change the flow cross-section, achieving cutting, reversing, or adjustment. The actuator should be selected according to the maximum pressure difference, valve stem thrust or output torque, and a reasonable margin should be reserved. When remote feedback, proportional adjustment, or interlocking is required, the requirements for power supply, control signals, valve position feedback, and electric actuators should be clearly defined during the ordering phase to avoid inconsistencies between accessory interfaces and on-site control logic.

Caliber pressure and material selection

The commonly used nominal diameter is DN15-DN200, and the pressure rating is PN10/PN16. The valve body material can be selected from PPH or UPVC, and its adaptability needs to be confirmed in combination with the corrosiveness of the medium, temperature cycling, particle content, and external environment. The allowable temperature, pressure difference, and leakage requirements of PTFE soft seal should be checked synchronously. For pipelines that are prone to crystallization, contain particles, frequently move, or have significant temperature changes, the wear resistance of valve internals, packing structure, support method, and erosion prevention measures should also be confirmed.

Product features and applicable industries

The main features of this product include corrosion resistance, remote switch, and flange connection. After reasonable configuration, it can be used for electroplating, environmental protection, chemical wastewater and water treatment systems. When dealing with flammable, explosive, highly corrosive, high-temperature, or toxic media, explosion-proof actuators, locators, solenoid valves, limit switches, and corresponding materials should be selected according to site specifications, and general parameters should not replace special safety reviews.

Installation and Debugging

Before installation, the nameplate, flow direction, connection standard, and sealing surface should be checked, welding slag and hard debris in the pipeline should be removed, and the front and rear pipe sections should be ensured to be concentric. It is forbidden to use valves to forcibly correct pipeline deviations. Maintenance space should be reserved around the actuator, and cable entrances should be waterproofed and protected according to the on-site environment. The first debugging should be carried out under low-risk conditions to check the fully open and fully closed positions, travel feedback, interlocking logic, sealing condition, and abnormal noise, and then gradually increase to the working pressure.

operation and maintenance

During operation, action time, valve position feedback, leakage, pressure difference, and control signals should be recorded. If the action is slow or the switching is not in place, the power supply, wiring, control module, valve position feedback, and electric actuator should be checked first, and then the valve stem, valve seat, and seals should be checked. It is not advisable to blindly increase the driving force. Before maintenance, it is necessary to isolate the medium, relieve pressure, and confirm that there is no residual energy; After replacing the seals, conduct strength, sealing, and action tests according to regulations, and keep records of spare parts materials and maintenance.

Q&A on the selection of electric corrosion-resistant ball valves

What media information is required before selecting Q941F-10P for corrosive media?

Please provide the composition, concentration, temperature, pressure, particles, and negative pressure of the medium, and check the valve body, lining, sphere, and seal item by item. Corrosion resistance does not mean that any lining material can be used or adapted to all chemical media.

When replacing the old flange ball valve with Q941F-10P, is it enough to only check DN and PN?

It is also necessary to verify the flange standard, sealing surface, structural length, valve body and seat materials, as well as the allowable pressure at operating temperature. The installation space and connection bracket of the actuator should also be confirmed together with the site.

Will Q941F-10P automatically shut down after a power outage?

The power-off action cannot be determined solely by the name of the electric drive. Ordinary electric actuator cannot default to having automatic valve closing function when power is lost; If the process requires fault closure, the energy storage or other fault safety scheme of the actuator should be confirmed at the time of ordering, and the entire valve interlock verification should be completed.

Order Information List

Suggest providing the composition of the medium, design and operating temperature, maximum and normal pressure, flow range, pipeline standards, operating frequency, power supply, control signals, valve position feedback and requirements for electric actuators, fail safe location, and environmental protection requirements. Fouten Flow Control (Jiangsu) Co., Ltd. will verify the caliber, material, seal, actuator, and accessory combination based on these materials to ensure that the product parameters are consistent with the actual pipeline conditions, and provide traceable basis for subsequent installation and maintenance.

More electric ball valves are availableSelection of electric ball valveThe structure and sealing selection of ball valves can be viewedBall valve manufacturer column。

Online message

Provide a phone number or work email; at least one is required.

Please send drawings to the official email shown on this page. This form does not accept attachments.