Fouten Fouten Fouten
15961836110
Electric regulating butterfly valve D941W-16P

Electric regulating butterfly valve D941W-16P

Product Features
Opening adjustment, metal sealing, flange connection
Model number
D941W-16P
Specification and caliber
DN50-DN600
Pressure level
PN16/PN25
Material
WCB/CF8/CF8M
Product Introduction

D941W-16P electric regulating butterfly valve

The electric regulating butterfly valve D941W-16P is suitable for on/off or process control in thermal pipelines, energy devices, and industrial water systems. Before selecting, it is necessary to confirm the composition of the medium, temperature, design pressure, normal and maximum flow rates, pressure difference before and after the valve, connection standards, and control signals. The model cannot be determined solely based on the pipe diameter. The parameters in this article are commonly used configurations and should ultimately be based on project conditions, order confirmation, and manufacturing drawings.

Structure and Drive

D941W-16P adopts flange connection, metal sealing, and eccentric butterfly plate structure. During operation, the angle stroke electric actuator drives the opening and closing components to change the flow area, achieving corresponding cutting or adjustment. When it comes to remote control, interlocking, or feedback, the control signal, power or gas source conditions, protection level, fault safety location, and accessory interfaces should be clearly defined during the ordering stage to avoid on-site configuration mismatch.

Material and sealing

The commonly used caliber is DN50-DN600, and the pressure rating is PN16/PN25. The valve body material is WCB/CF8/CF8M, and the seal adopts a metal hard seal. The selection of materials must take into account the corrosiveness of the medium, chloride ions, temperature fluctuations, particulate matter, and cleaning conditions; The allowable pressure difference, leakage level, and temperature range need to be checked synchronously. Under conditions of high temperature, easy crystallization, particle content, or frequent operation, the hardness of valve internals, packing structure, and erosion prevention measures should also be confirmed.

Product Specifications

Product ModelD941W-16P
Structural formFlange connection, metal seal, eccentric butterfly plate structure
Nominal DiameterDN50-DN600
pressure ratingPN16/PN25
Valve body materialWCB/CF8/CF8M
sealing formMetal hard seal
Drive TypeAngular stroke electric actuator
Applicable temperature-20℃ to 350℃, confirm according to material combination
Applicable MediumWater, steam, oil products, and general industrial gases

Applicable working conditions

Common features include opening adjustment, metal sealing, and flange connection, which can be used for thermal pipelines, energy devices, and industrial water systems. When used in explosion-proof areas, actuators, limit switches, solenoid valves, or locators should be configured according to the site zoning. When used in food, pharmaceutical, or high-purity media systems, further confirmation of the contact material, surface treatment, and cleaning plan is required; Projects involving flammable, toxic, or highly corrosive media should undergo specialized safety reviews.

Installation and Debugging

Before installation, check the nameplate, flow direction, and connection standards, remove welding slag and hard debris, and avoid transmitting pipeline stress to the valve body. Maintenance space should be reserved around the actuator; The cable entrance of the electric actuator should be waterproof, and the pneumatic accessories should use a clean and dry air source. The first debugging can be carried out by checking the switch position, travel feedback, interlocking logic, and sealing of connection parts in a low-risk state, and then gradually putting them into normal operation.

Operation and maintenance

During operation, action time, valve position feedback, abnormal noise, leakage, and control signals should be recorded. When there is a delay or inability to move in place, the power or gas source, wiring, filter pressure reducing valve, actuator, and control circuit should be checked first, and then the valve stem, valve seat, and seals should be checked. Blindly increasing the driving force is not advisable. Before maintenance, it is necessary to isolate the medium, relieve pressure, and confirm that there is no residual energy; After replacing spare parts, sealing and action tests should be conducted.

Q&A on the selection of electric regulating butterfly valves

D941W-16P pipeline is DN50, must the regulating valve also be selected as DN50?

not always. Please provide the minimum, normal, and maximum flow rates, upstream and downstream pressures, media, and temperature. First, calculate Cv/Kv and the available opening range, and then determine the valve diameter; Choosing too large may also make small flow regulation unstable.

Do I need to confirm the input signal and valve position feedback when connecting D941W-16P to DCS?

It is necessary to confirm the control input, valve position feedback, power or gas source conditions, interfaces, and fault location separately. Input and feedback are not the same function, and it cannot be assumed that all analog signals or communication protocols are fully equipped based solely on the name "regulating type".

Will D941W-16P automatically shut down after a power outage?

The power-off action cannot be determined solely by the name of the electric drive. Ordinary electric actuator cannot default to having automatic valve closing function when power is lost; If the process requires fault closure, the energy storage or other fault safety scheme of the actuator should be confirmed at the time of ordering, and the entire valve interlock verification should be completed.

Selection and ordering information

Suggest providing the name and composition of the medium, design and operating temperature, maximum and normal pressure, flow range, pipeline standards, operating frequency, control signals, power or gas supply conditions, fault safety location, and environmental protection requirements. Fouten Flow Control (Jiangsu) Co., Ltd. can be used to verify the caliber, material, seal, actuator, and accessory combination, retaining technical basis for installation and maintenance.

Online message

Provide a phone number or work email; at least one is required.

Please send drawings to the official email shown on this page. This form does not accept attachments.