Fouten Fouten Fouten
15961836110
Electric stainless steel globe valve J941W-16P

Electric stainless steel globe valve J941W-16P

Product Features
Reliable cut-off, travel control, remote opening and closing
Model number
J941W-16P
Specification and caliber
DN15-DN300
Pressure level
PN16/PN25
Material
CF8/CF8M
Product Introduction

J941W-16P electric stainless steel globe valve

Electric stainless steel globe valve J941W-16P is used for automatic switching or process control in chemical matching, steam pipelines, equipment isolation, and industrial pipeline networks. The selection should check the medium, temperature, maximum and normal flow rates, pressure difference before and after the valve, pipeline standards and control requirements, and should not be based solely on the existing pipe diameter. This article lists the commonly used configuration range, and the final data should be based on project conditions, order confirmation forms, and manufacturing drawings.

Structure and Drive

J941W-16P adopts a straight through cut-off type, flange connection, and upper sealing structure. When the fluid passes through the valve body flow channel, the multi turn electric actuator changes the position of the opening and closing components to complete cutting or adjustment. The actuator should match the torque or thrust of the valve and reserve a reasonable safety factor. When feedback, positioning, or interlocking is required, the control signal, power or gas source, protection level, and fault safety location should be clearly defined during the ordering phase to avoid on-site interface mismatch.

Material and sealing

The commonly used caliber is DN15-DN300, the pressure rating is PN16/PN25, and the valve body material can be selected as CF8/CF8M. The selection of materials should take into account the corrosiveness of the medium, chloride ions, temperature fluctuations, and cleaning conditions. The allowable temperature, pressure difference, and leakage level of metal seals should be checked simultaneously. For steam, particle containing, easily crystallized or frequently operated conditions, the hardness of valve internals, packing form and erosion prevention measures should also be confirmed.

Product Specifications

Product ModelJ941W-16P
Structural formStraight through cut-off type, flange connection, upper sealing structure
Nominal DiameterDN15-DN300
pressure ratingPN16/PN25
Valve body materialCF8/CF8M
sealing formmetal seal
Drive TypeMulti turn electric actuator
Applicable temperature-20℃ to 425℃, confirm according to the packing and valve seat
Applicable MediumWater, steam, oil and weakly corrosive media

Applicable working conditions

The product features include reliable cut-off, stroke control, remote opening and closing, and can be used for chemical matching, steam pipelines, equipment isolation, and industrial pipe networks after reasonable configuration. Dangerous areas should select corresponding actuators, accessories, and wiring methods according to explosion-proof zones; Food, pharmaceutical and other systems also need to confirm the requirements for liquid receiving materials, surface treatment and cleaning. Projects involving oxygen, highly corrosive or toxic media should undergo specialized material and safety reviews.

Installation and Debugging

Before installation, the nameplate, flow direction, and connection standards should be checked, and welding slag and hard debris should be removed to ensure the concentricity of the front and rear pipe sections and avoid the transmission of pipeline stress to the valve body. Maintain maintenance space around the actuator, and prevent rainwater from entering the cable entrance; Pneumatic accessories should use a clean and dry air source. The first debugging should check the switch position, stroke feedback, interlocking logic, and sealing condition under low-risk conditions, and then gradually enter the working pressure.

Operation and maintenance

Observe action time, abnormal noise, leakage, valve position feedback, and control signals during operation. When the action is slow, first check the power or gas source, wiring, filter pressure reducing valve, and actuator, and then check the valve stem, valve seat, and seals. It is not advisable to blindly increase the driving force. Before maintenance, it is necessary to isolate the medium, relieve pressure, and confirm that there is no residual energy. After replacing the seal, conduct strength, sealing, and action tests according to regulations, and record the material of the spare parts and the date of maintenance.

Q&A on the selection of electric stainless steel globe valve

Can J941W-16P switch directly under large pressure differences?

The valve internals, valve stem, and actuator output force should be checked against the maximum closing pressure difference, and the actual flow direction should be confirmed. The nominal pressure of the valve body cannot be directly used as the allowable opening and closing pressure difference, and the problem of loose closure cannot be solved by blindly increasing the driving force.

Can the old globe valve be directly replaced with J941W-16P with the same diameter?

It is also necessary to verify the flange standards, sealing surfaces, structural length, flow direction, and allowable pressure of materials at working temperature; The same caliber does not guarantee the same connection size and opening and closing capacity.

Will J941W-16P automatically shut down after a power outage?

The power-off action cannot be determined solely by the name of the electric drive. Ordinary electric actuator cannot default to having automatic valve closing function when power is lost; If the process requires fault closure, the energy storage or other fault safety scheme of the actuator should be confirmed at the time of ordering, and the entire valve interlock verification should be completed.

Selection and ordering information

Suggest providing the composition of the medium, design and operating temperature, maximum and normal pressure, flow range, pipeline standards, operating frequency, control signals, power or gas supply conditions, fail safe location, and environmental protection requirements. Fouten Flow Control (Jiangsu) Co., Ltd. will verify the caliber, material, seal, actuator, and accessory combination based on this, providing traceable basis for installation and maintenance.

Online message

Provide a phone number or work email; at least one is required.

Please send drawings to the official email shown on this page. This form does not accept attachments.

Home Home Valve selectionValve selection news informationnews information Contact usContact us