Fouten Fouten Fouten
15961836110
Electric soft seal butterfly valve D941X-16Q

Electric soft seal butterfly valve D941X-16Q

Product Features
Elastic seal, flange installation, remote switch
Model number
D941X-16Q
Specification and caliber
DN50-DN1200
Pressure level
PN16
Material
Ductile iron/carbon steel
Product Introduction

D941X-16Q electric soft seal butterfly valve

Electric soft seal butterfly valve D941X-16Q is used for automatic switching or process control in water supply and drainage, HVAC, water treatment, and municipal engineering. The selection should check the medium, temperature, maximum and normal flow rates, pressure difference before and after the valve, pipeline standards and control requirements, and should not be based solely on the existing pipe diameter. This article lists the commonly used configuration range, and the final data should be based on project conditions, order confirmation forms, and manufacturing drawings.

Structure and Drive

D941X-16Q adopts flange connection, centerline butterfly plate, and elastic valve seat. When the fluid passes through the valve body flow channel, the position of the opening and closing parts is changed by the angular stroke electric actuator to complete cutting or adjustment. The actuator should match the torque or thrust of the valve and reserve a reasonable safety factor. When feedback, positioning, or interlocking is required, the control signal, power or gas source, protection level, and fault safety location should be clearly defined during the ordering phase to avoid on-site interface mismatch.

Material and sealing

The commonly used caliber is DN50-DN1200, the pressure rating is PN16, and the valve body material can be selected from ductile iron/carbon steel. The selection of materials should take into account the corrosiveness of the medium, chloride ions, temperature fluctuations, and cleaning conditions. EPDM or NBR soft seals should have their allowable temperature, pressure difference, and leakage level checked simultaneously. For steam, particle containing, easily crystallized or frequently operated conditions, the hardness of valve internals, packing form and erosion prevention measures should also be confirmed.

Product Specifications

Product ModelD941X-16Q
Structural formFlange connection, center butterfly plate, elastic valve seat
Nominal DiameterDN50-DN1200
pressure ratingPN16
Valve body materialDuctile iron/carbon steel
sealing formEPDM or NBR soft seal
Drive TypeAngular stroke electric actuator
Applicable temperature-10℃ to 120℃, confirm according to the sealing material
Applicable MediumWater, air, and general non corrosive media

Applicable working conditions

The product features include elastic sealing, flange installation, remote switch, and can be used for water supply and drainage, HVAC, water treatment, and municipal engineering after reasonable configuration. Dangerous areas should select corresponding actuators, accessories, and wiring methods according to explosion-proof zones; Food, pharmaceutical and other systems also need to confirm the requirements for liquid receiving materials, surface treatment and cleaning. Projects involving oxygen, highly corrosive or toxic media should undergo specialized material and safety reviews.

Installation and Debugging

Before installation, the nameplate, flow direction, and connection standards should be checked, and welding slag and hard debris should be removed to ensure the concentricity of the front and rear pipe sections and avoid the transmission of pipeline stress to the valve body. Maintain maintenance space around the actuator, and prevent rainwater from entering the cable entrance; Pneumatic accessories should use a clean and dry air source. The first debugging should check the switch position, stroke feedback, interlocking logic, and sealing condition under low-risk conditions, and then gradually enter the working pressure.

Operation and maintenance

Observe action time, abnormal noise, leakage, valve position feedback, and control signals during operation. When the action is slow, first check the power or gas source, wiring, filter pressure reducing valve, and actuator, and then check the valve stem, valve seat, and seals. It is not advisable to blindly increase the driving force. Before maintenance, it is necessary to isolate the medium, relieve pressure, and confirm that there is no residual energy. After replacing the seal, conduct strength, sealing, and action tests according to regulations, and record the material of the spare parts and the date of maintenance.

Q&A on selection of electric soft seal butterfly valve

How to choose a soft sealing ring for D941X-16Q in contact with oil media?

It is necessary to specify the specific oil product, temperature, pressure, and cleaning medium, and verify the compatibility between the valve seat and the seal. Applicability cannot be judged solely based on whether the valve body is made of stainless steel or ductile iron, nor can different rubber materials be directly interchanged.

Can D941X-16Q directly replace the original flange butterfly valve?

Please provide the connection standard, structural length, sealing surface, and on-site space of the old valve, and verify the driving height and flow direction requirements of the new valve. It cannot be determined that direct replacement can be made solely based on the same caliber and nominal pressure.

Will D941X-16Q automatically shut down after a power outage?

The power-off action cannot be determined solely by the name of the electric drive. Ordinary electric actuator cannot default to having automatic valve closing function when power is lost; If the process requires fault closure, the energy storage or other fault safety scheme of the actuator should be confirmed at the time of ordering, and the entire valve interlock verification should be completed.

Selection and ordering information

Suggest providing the composition of the medium, design and operating temperature, maximum and normal pressure, flow range, pipeline standards, operating frequency, control signals, power or gas supply conditions, fail safe location, and environmental protection requirements. Fouten Flow Control (Jiangsu) Co., Ltd. will verify the caliber, material, seal, actuator, and accessory combination based on this, providing traceable basis for installation and maintenance.

Online message

Provide a phone number or work email; at least one is required.

Please send drawings to the official email shown on this page. This form does not accept attachments.

Home Home Valve selectionValve selection news informationnews information Contact usContact us