Fouten Fouten Fouten
15961836110
Electric high-pressure gate valve Z941H-25C

Electric high-pressure gate valve Z941H-25C

Product Features
High voltage level, fully open low resistance, remote opening and closing
Model number
Z941H-25C
Specification and caliber
DN50-DN500
Pressure level
PN25
Material
WCB
Product Introduction

Z941H-25C electric high-pressure gate valve

Electric high-pressure gate valve Z941H-25C is used for automatic switching or process control in thermal pipelines, boiler auxiliary equipment, energy devices, and industrial pipelines. The selection should check the medium, temperature, maximum and normal flow rates, pressure difference before and after the valve, pipeline standards and control requirements, and should not be based solely on the existing pipe diameter. This article lists the commonly used configuration range, and the final data should be based on project conditions, order confirmation forms, and manufacturing drawings.

Structure and Drive

Z941H-25C adopts flange connection, wedge gate, and rising rod structure. When the fluid passes through the valve body flow channel, the multi turn electric actuator changes the position of the opening and closing components to complete cutting or adjustment. The actuator should match the torque or thrust of the valve and reserve a reasonable safety factor. When feedback, positioning, or interlocking is required, the control signal, power or gas source, protection level, and fault safety location should be clearly defined during the ordering phase to avoid on-site interface mismatch.

Material and sealing

The commonly used caliber is DN50-DN500, the pressure rating is PN25, and the valve body material can be selected as WCB. The selection of materials should take into account the corrosiveness of the medium, chloride ions, temperature fluctuations, and cleaning conditions. The allowable temperature, pressure difference, and leakage level of metal seals should be checked simultaneously. For steam, particle containing, easily crystallized or frequently operated conditions, the hardness of valve internals, packing form and erosion prevention measures should also be confirmed.

Product Specifications

Product ModelZ941H-25C
Structural formFlange connection, wedge gate, and exposed rod structure
Nominal DiameterDN50-DN500
pressure ratingPN25
Valve body materialWCB
sealing formmetal seal
Drive TypeMulti turn electric actuator
Applicable temperature-20℃ to 425℃, confirm according to the packing and valve seat
Applicable MediumSteam, hot water, oil products, and general industrial gases

Applicable working conditions

The product features include high pressure rating, fully open low resistance, remote opening and closing. After reasonable configuration, it can be used for thermal pipelines, boiler auxiliary equipment, energy devices, and industrial pipelines. Dangerous areas should select corresponding actuators, accessories, and wiring methods according to explosion-proof zones; Food, pharmaceutical and other systems also need to confirm the requirements for liquid receiving materials, surface treatment and cleaning. Projects involving oxygen, highly corrosive or toxic media should undergo specialized material and safety reviews.

Installation and Debugging

Before installation, the nameplate, flow direction, and connection standards should be checked, and welding slag and hard debris should be removed to ensure the concentricity of the front and rear pipe sections and avoid the transmission of pipeline stress to the valve body. Maintain maintenance space around the actuator, and prevent rainwater from entering the cable entrance; Pneumatic accessories should use a clean and dry air source. The first debugging should check the switch position, stroke feedback, interlocking logic, and sealing condition under low-risk conditions, and then gradually enter the working pressure.

Operation and maintenance

Observe action time, abnormal noise, leakage, valve position feedback, and control signals during operation. When the action is slow, first check the power or gas source, wiring, filter pressure reducing valve, and actuator, and then check the valve stem, valve seat, and seals. It is not advisable to blindly increase the driving force. Before maintenance, it is necessary to isolate the medium, relieve pressure, and confirm that there is no residual energy. After replacing the seal, conduct strength, sealing, and action tests according to regulations, and record the material of the spare parts and the date of maintenance.

Q&A on Selection of Electric High Pressure Gate Valve

Can Z941H-25C be used with a half open valve instead of a regulating valve to control flow?

Ordinary cut-off gate valves should not be directly treated as continuous regulating valves. Long term semi opening may cause erosion or vibration to the gate and valve seat; It should be clarified whether the process requires opening and closing isolation or continuous regulation before selecting the corresponding valve type.

How much maintenance space is needed for Z941H-25C installed under the equipment?

The full stroke height of the valve stem, bracket, and actuator should be checked according to the specific assembly drawing, and space for disassembly and assembly should be reserved; The length of the valve body alone cannot be used to determine whether it can be installed. The visible stem structure also needs to be checked for interference between the valve stem extension path and the equipment.

Will Z941H-25C automatically shut down after a power outage?

The power-off action cannot be determined solely by the name of the electric drive. Ordinary electric actuator cannot default to having automatic valve closing function when power is lost; If the process requires fault closure, the energy storage or other fault safety scheme of the actuator should be confirmed at the time of ordering, and the entire valve interlock verification should be completed.

Selection and ordering information

Suggest providing the composition of the medium, design and operating temperature, maximum and normal pressure, flow range, pipeline standards, operating frequency, control signals, power or gas supply conditions, fail safe location, and environmental protection requirements. Fouten Flow Control (Jiangsu) Co., Ltd. will verify the caliber, material, seal, actuator, and accessory combination based on this, providing traceable basis for installation and maintenance.

Online message

Provide a phone number or work email; at least one is required.

Please send drawings to the official email shown on this page. This form does not accept attachments.

Home Home Valve selectionValve selection news informationnews information Contact usContact us