Fouten Fouten Fouten
15961836110
Electric single seat regulating valve ZDLP-16C

Electric single seat regulating valve ZDLP-16C

Product Features
Proportional adjustment, position feedback, low leakage
Model number
ZDLP-16C
Specification and caliber
DN20-DN200
Pressure level
PN16/PN25
Material
WCB/CF8
Product Introduction

ZDLP-16C electric single seat regulating valve

Product Specifications

Product ModelZDLP-16C
Structural formDirect single seat plunger structure
Nominal DiameterDN20-DN200
pressure ratingPN16/PN25
Valve body materialWCB/CF8
sealing formMetal hard seal/PTFE soft seal
Drive TypeIntelligent linear electric actuator
Applicable temperature-20℃ to 350℃
Applicable MediumWater, steam, air, and process media

Structure and Application

The ZDLP-16C electric single seat regulating valve adopts a straight through single seat plunger structure, which is designed for automatic opening and closing or flow control in HVAC, chemical, power and process automation. The single seat valve core is matched with a linear actuator to achieve continuous adjustment, which is suitable for control circuits with relatively stable pressure difference. Project selection should not only be based on the connection diameter, but should also synchronously confirm the medium state, design pressure, normal temperature, maximum pressure difference, operating frequency, allowable leakage level, and on-site control signals to avoid mismatch between valve mechanical capabilities and system operating conditions.

Specifications and materials

The nominal diameter of this model covers DN20-DN200, with a pressure rating of PN16/PN25. The valve body material can be configured according to WCB/CF8. Material selection should take into account the corrosiveness of the medium, chloride ion content, erosion particles, and environmental temperature; When there are low temperature, high temperature or frequent thermal cycles, the material combination of the valve stem, fasteners and packing should also be checked, and the diameter and pressure standards should be unified in the ordering documents.

Sealing and Media

ZDLP-16C uses metal hard seal/PTFE soft seal, suitable for temperature range from - 20℃ to 350℃. The choice of sealing pair will affect the closing performance, operating torque, and maintenance cycle. For media such as water, steam, air, and process media, the risks of scaling, wear, adhesion, and cavitation should be evaluated separately; When a stricter leakage level is required, the sealing form should be determined under the premise of meeting temperature and pressure difference conditions, and a single material cannot cover all working conditions.

Drive and Control

The driving part adopts an intelligent linear electric actuator, which can be configured with switch values, analog values, valve position feedback, limit switches, and fault interlocks according to the control scheme. The output force or torque of the actuator should have a reasonable safety margin, while verifying the action time and power or gas source conditions. The protection level of control cabinets, junction boxes, and accessories should be suitable for indoor, outdoor, humid, or hazardous environments.

Installation requirements

Before installation, the nameplate parameters, flow direction identification, connection dimensions, and random files should be checked, and welding slag, iron filings, and sealing residues in the pipeline should be removed. The pipelines at both ends of the valve must be coaxial and independently supported, and it is forbidden to forcefully straighten them with fastening bolts. When lifting, the valve body or designated lifting point should be selected, and cables, air pipes, handwheels, and actuator housings should not be used as load-bearing points.

debugging method

The first debugging requires completing a full stroke test under safe isolation conditions, recording the switch position, action time, feedback signal, operating current or gas source pressure. The adjustment purpose should also check the correspondence between the input signal and the actual valve position, and if necessary, perform zero point, range, and dead zone calibration. When encountering jamming, abnormal noise, vibration, or misalignment, the continuous operation should be stopped and the mechanical or control cause should be identified.

operation and maintenance

After being put into operation, a spot check cycle can be established based on the cleanliness of the medium and the number of actions, with a focus on inspecting connecting bolts, valve stem areas, sealing surfaces, actuators, limit devices, and electrical or pneumatic accessories. If there is external leakage, internal leakage, slow response or valve position drift, the problem should be judged based on the process trend to determine whether it comes from the valve internals, driving device or control circuit, in order to avoid increasing the driving force without diagnosis.

Maintenance safety

Before maintenance, the process medium must be cut off, the pressure in the valve chamber must be released, and all power sources must be isolated. During the disassembly process, record the direction and pre tightening status of the parts, and after replacing the seals, tighten them evenly in the prescribed order. Static sealing, movement, and interlocking checks should be conducted before reusing; When dealing with high temperature, flammable or toxic media, on-site work permits, replacement and testing requirements must also be followed.

Selection Guide

Proportional adjustment, position feedback, and low leakage are the main application features of this product, but actual performance depends on correct caliber calculation, material selection, and control parameters. For transient conditions such as minimum flow rate, bypass operation, pump start stop, or system water hammer, they should be jointly reviewed by the process and self-control specialties. The project documentation should clearly state the medium name, flow range, upstream and downstream pressure, and failure location to facilitate the formation of traceable selection criteria.

order proposals

Fouten Flow Control (Jiangsu) Co., Ltd. suggests providing operating condition data sheets, pipeline grades, connection standards, control signals, and accessory lists when purchasing ZDLP-16C. After arrival, verify the physical object and technical agreement, and save the debugging records and vulnerable parts information. By standardizing selection, installation, commissioning, and periodic maintenance, the operational stability of electric single seat regulating valves in HVAC, chemical, power, and process automation can be improved, and the risk of unplanned shutdowns can be reduced.

Common problems in product selection

ZDLP-16C pipeline is DN50, must the regulating valve also be selected as DN50?

not always. Please provide the minimum, normal, and maximum flow rates, upstream and downstream pressures, media, and temperature. First, calculate Cv/Kv and the available opening range, and then determine the valve diameter; Choosing too large may also make small flow regulation unstable.

Do I need to confirm the input signal and valve position feedback when connecting ZDLP-16C to DCS?

It is necessary to confirm the control input, valve position feedback, power or gas source conditions, interfaces, and fault location separately. Input and feedback are not the same function, and it cannot be assumed that all analog signals or communication protocols are fully equipped based solely on the name "regulating type".

Will ZDLP-16C automatically shut down after a power outage?

The power-off action cannot be determined solely by the name of the electric drive. Ordinary electric actuator cannot default to having automatic valve closing function when power is lost; If the process requires fault closure, the energy storage or other fault safety scheme of the actuator should be confirmed at the time of ordering, and the entire valve interlock verification should be completed.

Online message

Provide a phone number or work email; at least one is required.

Please send drawings to the official email shown on this page. This form does not accept attachments.

Home Home Valve selectionValve selection news informationnews information Contact usContact us