Fouten Fouten Fouten
15961836110
Electric wedge gate valve Z941Y-25C

Electric wedge gate valve Z941Y-25C

Product Features
Fully open and fully closed, valve position indication, remote interlocking
Model number
Z941Y-25C
Specification and caliber
DN50-DN500
Pressure level
PN16/PN25
Material
WCB/WC6
Product Introduction

Z941Y-25C electric wedge gate valve

Product Specifications

Product ModelZ941Y-25C
Structural formFlange connected open stem wedge gate
Nominal DiameterDN50-DN500
pressure ratingPN16/PN25
Valve body materialWCB/WC6
sealing formHard alloy sealing surface
Drive TypeMulti turn electric actuator
Applicable temperature-29℃ to 425℃
Applicable MediumWater, steam, oil and non corrosive media

Structure and Application

The Z941Y-25C electric wedge gate valve adopts a flange connected rising stem wedge gate, which is used for automatic opening and closing or flow control of power stations, petrochemicals, heating and industrial transmission pipelines. Wedge gate is used for low flow resistance cutting, and the multi turn actuator provides torque protection and switch position management. Project selection should not only be based on the connection diameter, but should also synchronously confirm the medium state, design pressure, normal temperature, maximum pressure difference, operating frequency, allowable leakage level, and on-site control signals to avoid mismatch between valve mechanical capabilities and system operating conditions.

Specifications and materials

The nominal diameter of this model covers DN50-DN500, with a pressure rating of PN16/PN25. The valve body material can be configured according to WCB/WC6. Material selection should take into account the corrosiveness of the medium, chloride ion content, erosion particles, and environmental temperature; When there are low temperature, high temperature or frequent thermal cycles, the material combination of the valve stem, fasteners and packing should also be checked, and the diameter and pressure standards should be unified in the ordering documents.

Sealing and Media

Z941Y-25C uses hard alloy sealing surface, suitable for temperature range from - 29℃ to 425℃. The choice of sealing pair will affect the closing performance, operating torque, and maintenance cycle. For media such as water, steam, oil, and non corrosive media, the risks of scaling, wear, adhesion, and cavitation should be evaluated separately; When a stricter leakage level is required, the sealing form should be determined under the premise of meeting temperature and pressure difference conditions, and a single material cannot cover all working conditions.

Drive and Control

The driving part adopts a multi turn electric actuator, which can be configured with switch values, analog values, valve position feedback, limit switches, and fault interlocks according to the control scheme. The output force or torque of the actuator should have a reasonable safety margin, while verifying the action time and power or gas source conditions. The protection level of control cabinets, junction boxes, and accessories should be suitable for indoor, outdoor, humid, or hazardous environments.

Installation requirements

Before installation, the nameplate parameters, flow direction identification, connection dimensions, and random files should be checked, and welding slag, iron filings, and sealing residues in the pipeline should be removed. The pipelines at both ends of the valve must be coaxial and independently supported, and it is forbidden to forcefully straighten them with fastening bolts. When lifting, the valve body or designated lifting point should be selected, and cables, air pipes, handwheels, and actuator housings should not be used as load-bearing points.

debugging method

The first debugging requires completing a full stroke test under safe isolation conditions, recording the switch position, action time, feedback signal, operating current or gas source pressure. The adjustment purpose should also check the correspondence between the input signal and the actual valve position, and if necessary, perform zero point, range, and dead zone calibration. When encountering jamming, abnormal noise, vibration, or misalignment, the continuous operation should be stopped and the mechanical or control cause should be identified.

operation and maintenance

After being put into operation, a spot check cycle can be established based on the cleanliness of the medium and the number of actions, with a focus on inspecting connecting bolts, valve stem areas, sealing surfaces, actuators, limit devices, and electrical or pneumatic accessories. If there is external leakage, internal leakage, slow response or valve position drift, the problem should be judged based on the process trend to determine whether it comes from the valve internals, driving device or control circuit, in order to avoid increasing the driving force without diagnosis.

Maintenance safety

Before maintenance, the process medium must be cut off, the pressure in the valve chamber must be released, and all power sources must be isolated. During the disassembly process, record the direction and pre tightening status of the parts, and after replacing the seals, tighten them evenly in the prescribed order. Static sealing, movement, and interlocking checks should be conducted before reusing; When dealing with high temperature, flammable or toxic media, on-site work permits, replacement and testing requirements must also be followed.

Selection Guide

The main application features of this product are fully open and fully closed, valve position indication, and remote interlocking, but the actual performance depends on the correct caliber calculation, material selection, and control parameters. For transient conditions such as minimum flow rate, bypass operation, pump start stop, or system water hammer, they should be jointly reviewed by the process and self-control specialties. The project documentation should clearly state the medium name, flow range, upstream and downstream pressure, and failure location to facilitate the formation of traceable selection criteria.

order proposals

Fouten Flow Control (Jiangsu) Co., Ltd. suggests providing operating condition data sheets, pipeline grades, connection standards, control signals, and accessory lists when purchasing Z941Y-25C. After arrival, verify the physical object and technical agreement, and save the debugging records and vulnerable parts information. By standardizing selection, installation, commissioning, and periodic maintenance, the operational stability of electric wedge gate valves in power plants, petrochemicals, heating, and industrial pipelines can be improved, and the risk of unplanned shutdowns can be reduced.

Common problems in product selection

Can Z941Y-25C be used with a half open valve instead of a regulating valve to control flow?

Ordinary cut-off gate valves should not be directly treated as continuous regulating valves. Long term semi opening may cause erosion or vibration to the gate and valve seat; It should be clarified whether the process requires opening and closing isolation or continuous regulation before selecting the corresponding valve type.

How much maintenance space is needed for Z941Y-25C installed under the equipment?

The full stroke height of the valve stem, bracket, and actuator should be checked according to the specific assembly drawing, and space for disassembly and assembly should be reserved; The length of the valve body alone cannot be used to determine whether it can be installed. The visible stem structure also needs to be checked for interference between the valve stem extension path and the equipment.

Will Z941Y-25C automatically shut down after a power outage?

The power-off action cannot be determined solely by the name of the electric drive. Ordinary electric actuator cannot default to having automatic valve closing function when power is lost; If the process requires fault closure, the energy storage or other fault safety scheme of the actuator should be confirmed at the time of ordering, and the entire valve interlock verification should be completed.