Valve selection
Electric Ceramic Ball Valve Q941TC-16C
| Specification | Value |
|---|---|
| Model number | Q941TC-16C |
| Specification and caliber | DN25-DN300 |
| Pressure level | PN16 |
| Material | WCB |
| Product Features | Selection data for particle-containing conditions, electric control and overload judgment, pipeline cleaning and ceramic protection |
The Q941TC-16C electric ceramic ball valve is used for remote on/off control of compatible slurry containing particles. The ceramic ball and seat are in the main abrasion and sealing area, while the WCB body bears the connection and pressure. The electric actuator drives the ball core through the valve shaft. Particle scouring and the starting and closing contact after deposition jointly determine the internal components and drive configuration.
Product Parameters
| Product Model | Q941TC-16C |
|---|---|
| Structure Type | Flanged connection, ceramic ball and seat |
| Nominal Diameter | DN25-DN300 |
| Pressure Rating | PN16 |
| Body Material | WCB |
| Sealing Type | Ceramic sealing pair |
| Actuation Method | Electric actuator, power supply and working mode determined by project |
| Applicable Temperature | Specific temperature and thermal shock limits confirmed by ceramic and auxiliary seals |
| Applicable Medium | Confirmed particle-containing slurries and abrasive fluids |
How to Choose Ball Port, Seat, and Liner
When the ball port opens, a passage is formed, and when closed, the ball surface contacts the seat. Continuously flowing fine particles will scour these surfaces, while larger particles may get trapped at the closing edge; two slurries with the same solid content may cause different damage due to differences in particle size and hardness. Comparing the normal transport, settling during downtime, and flushing phases helps in selecting ceramic internal components, auxiliary seals, and front-end debris removal solutions.
Electric Control and Overload Judgment
The actuator bears different torques during starting, rotation, and seating phases. The protection settings must allow normal sealing to establish while limiting abnormal jamming effects on the valve shaft and ceramic components. For starting alarms, first check for settling and starting pressure differences; for fixed intermediate position alarms, check for foreign objects and local interference; for endpoint alarms, compare the actual closed position with the limit position. If the task is frequent continuous adjustment, use a valve core and actuator working mode suitable for the flow pressure difference and action frequency.
Pipeline Cleaning and Ceramic Protection
During installation, allow the flanges at both ends to align naturally, with supports bearing the weight of the pipe section and actuator to reduce offset loads on the ceramic internal components. In the cleaning phase, first remove welding slag, metal shavings, and hard debris, then gradually establish working conditions. When alternating hot and cold media, control the cutting-in process according to the allowable temperature difference of the ceramic and auxiliary seals. If cracks or chipping are found during maintenance, replace the corresponding components and recheck assembly, actual stroke, and shut-off performance.
Installation and Commissioning
Flanges should align naturally, with the pipe section and drive supported; after cleaning, verify direction, actual stroke, and feedback under controlled conditions, then gradually establish working conditions. Hot media should cut in according to the allowable temperature difference.
Maintenance and Reassembly
Before internal inspection, isolate the medium, relieve pressure, and control the driving energy. Replace damaged internal components as needed, and after reassembly, verify actual end position, feedback, and sealing; also address any material jamming, offset loads, or thermal shock sources.
Frequently Asked Questions
What to check if there is a torque alarm when starting the electric ceramic ball valve?
First, record the downtime, upstream and downstream pressures, and alarm angle. If the alarm occurs after a long stop, check for sediment; if at a fixed intermediate angle, check for foreign objects or local interference; when approaching the closed position, compare the limit position and sealing contact. Isolate, relieve pressure, and control unexpected actuator movements before internal inspection.
How to configure for long-term small opening flow adjustment?
Select the adjustment internal component capacity based on minimum, normal, and maximum flow and their pressure differences, and compare particle scouring and cavitation conditions at small openings. The actuator should adopt a working mode suitable for continuous positioning, with the valve core and seat both meeting throttling tasks.
If the ceramic part has chipping, can it be ground smooth and continued to use?
Chipping may alter sealing contact and local stress; it should be replaced according to the corresponding spare parts plan, and check for sources of impact, material jamming, or offset loads. After reassembly, verify actual stroke and leakage to prevent repeated damage.
What information is needed when ordering?
Please specify particle shape and hardness, solid content, viscosity, settling, temperature variations, and maximum closing pressure difference. List materials separately for ceramics, auxiliary seals, and metal shells, and for the actuator, list signals, power supply, working mode, and torque protection.
If long-term small opening operation is required, provide flow range and pressure difference for reassessment, and do not use cut-off type photos or drive signals as proof of adjustment performance.
For similar products, please browse the Electric Valve section, ensuring to compare under the same medium and control conditions.

news information