Fouten Fouten Fouten
15961836110
Electric switch type intelligent rising stem knife gate valve

Electric switch type intelligent rising stem knife gate valve

Product Features
Electric intelligent switch or electric intelligent adjustment
Model number
DZ973X
Specification and caliber
DN50-DN2000
Pressure level
PN6/PN10
Material
Ductile iron QT450, cast steel WCB
Product Introduction

Product Structure and Drivers

The DZ973X electric rising-stem knife gate valve uses an electric drive and transmission to move the stem and gate linearly across the passage. PN6 and PN10 configurations and QT450 ductile-iron or WCB cast-steel body options serve different pressure and material requirements. The actuator and transmission are sized for the gate load, travel and operating frequency.

Switch control and valve position control

An on-off actuator moves between the open and closed endpoints. An intermediate-position arrangement also needs compatible command, position feedback and travel control. The transmission torque and gate thrust are related through the mechanism, so actuator selection considers the required linear load as well as input torque. Power supply, communication and signal interfaces are selected as part of the control configuration.

Is the knife gate valve suitable for continuous adjustment?

At partial opening, the gate edge and seat may see concentrated flow and particle impact. This affects wear and control behaviour differently from full-open isolation service. A continuous-throttling application therefore calls for evaluating the gate and seat arrangement, solids, pressure drop and normal operating position together.

Drive and control selection

A control specification starts with the task: local or remote on-off operation, required feedback, operating frequency and the intended response to power loss. The selected actuator and any energy-storage arrangement implement that response. Installation planning also leaves clearance for the rising stem, drive removal and gate maintenance.

Penetrating electric structure can be viewedStainless steel 304 electric clamp penetrating knife gate valveFor more knife gate valves, please refer togate valves。

Frequently Asked Questions

Can the DZ973X communicate with our control system?

The selected actuator and control module determine supported protocols and signals. Specify the system interface, power supply and required feedback so the supplied configuration can be matched to it.

We need a valve to stop at intermediate positions. What changes?

The actuator needs compatible positioning control and feedback. The gate and seat must also suit the pressure drop, solids and sustained partial-opening duty.

Will an intelligent electric valve close when the power fails?

An ordinary motor drive loses its energy source and may remain in place. A defined failure action requires a suitable stored-energy or backup-power arrangement and control logic, assessed for the intended safety function.

FOUTEN

Discuss your valve configuration and quotation

Provide a phone number or work email; at least one is required.

Additional service and connection details (optional)

Please send drawings to the official email shown on this page. This form does not accept attachments.