Fouten Fouten Fouten
15961836110
Carbon cast steel manual worm gear transmission upper mounted flange eccentric hemispherical valve

Carbon cast steel manual worm gear transmission upper mounted flange eccentric hemispherical valve

Product Features
上装,蜗轮蜗杆,偏心半球
Model number
PB341F
Specification and caliber
DN50-DN1000
Pressure level
PN16-PN64,Class150-Class900
Material
WCB/304/316L
Product Introduction

This top-entry eccentric hemispherical valve uses a handwheel and worm gearbox to rotate the closure member. Eccentric movement separates the sealing surfaces during opening and brings them together near the closed position. The top-entry arrangement provides access to the internal parts from above; maintenance requires isolation, depressurization and sufficient overhead dismantling space.

The handwheel turns the worm, which drives the worm wheel and delivers reduced-speed rotary torque to the valve shaft and hemispherical closure. Eccentric movement separates the sealing surfaces as the valve opens and brings them into contact near closure. Gear reduction reduces the handwheel effort required for a given output torque. Actual operating load also depends on differential pressure, seat contact and deposits. A sudden increase in effort calls for locating the resistance before applying further force.

Top entry describes access to the internals through the upper body opening. The cover, shaft and trim removal path determine the clearance needed around the valve. Insulation, platforms and adjacent piping should leave that path available. Isolate, depressurize and remove residual process material before opening the cover. The maintenance procedure and available space determine whether the body can remain in the line.

For isolation service, select the body and sealing arrangement for the fluid, temperature, working differential pressure, flow direction and solids present. Sustained operation at intermediate positions also calls for evaluating flow characteristics, local velocity and pressure drop. Handwheel position indicates closure angle; the flow at that angle changes with the system pressure conditions. Fluid data, operating frequency and installation dimensions help match the valve and gearbox to the duty.

Does the closure rotate once for every handwheel revolution?

No. The gearbox reduces the multiple input turns to the designed valve travel. The gear ratio determines input turns, while valve travel and stops establish the open and closed positions.

Where is maintenance clearance needed on a top-entry valve?

Leave clearance above the cover and along the shaft and trim removal path. Isolate, depressurize and drain the valve before following its dismantling procedure.

What should be checked if closing suddenly requires more effort?

Under safe isolated conditions, distinguish resistance in the gearbox, shaft and trim. Deposits, seat contact and stop settings require different remedies; extending the handwheel lever can overload the drive.

FOUTEN

Discuss your valve configuration and quotation

Provide a phone number or work email; at least one is required.

Additional service and connection details (optional)

Please send drawings to the official email shown on this page. This form does not accept attachments.

Home Home Valve selectionValve selection news informationnews information Contact usContact us