Fouten Fouten Fouten
15961836110
Pneumatic fluoropolymer-lined ball valve Q641F46-16C

Pneumatic fluoropolymer-lined ball valve Q641F46-16C

Product Features
Corrosion resistance, quick cutting, optional gas loss position
Model number
Q641F46-16C
Specification and caliber
DN15-DN200
Pressure level
PN16
Material
WCB fluorine lining
Product Introduction

Q641F46-16C Pneumatic fluoropolymer-lined Ball Valve

Pneumatic fluoropolymer-lined ball valve Q641F46-16C is suitable for switching, cutting off, or process control in chemical reactions, acid-base transportation, and environmental protection devices. Before selecting, it is necessary to confirm the composition of the medium, temperature, design pressure, normal and maximum flow rates, pressure difference before and after the valve, connection standards, and control signals. The model cannot be determined solely based on the pipe diameter. The parameters in this article are commonly used configurations and should ultimately be based on project conditions, order confirmation, and manufacturing drawings.

Structure and Drive

Q641F46-16C adopts a two-piece straight channel, flange connection, and floating ball structure. During operation, the opening and closing components are driven by a double acting or single acting pneumatic actuator to change the flow area and achieve corresponding cutting or adjustment. When it comes to remote control, interlocking, or feedback, the requirements for gas source pressure, control signals, and accessories such as solenoid valves or positioners should be clearly defined during the ordering stage to avoid on-site configuration mismatch.

Material and sealing

The commonly used caliber is DN15-DN200, and the pressure rating is PN16. The valve body material is WCB lined with fluorine, and the seal adopts PTFE lined seal. The selection of materials must take into account the corrosiveness of the medium, chloride ions, temperature fluctuations, particulate matter, and cleaning conditions; The allowable pressure difference, leakage level, and temperature range need to be checked synchronously. Under conditions of high temperature, easy crystallization, particle content, or frequent operation, the hardness of valve internals, packing structure, and erosion prevention measures should also be confirmed.

Product Specifications

Product ModelQ641F46-16C
Structural formTwo piece straight channel, flange connection, floating ball structure
Nominal DiameterDN15-DN200
pressure ratingPN16
Valve body materialWCB fluorine lining
sealing formPTFE lining seal
Drive TypeDouble acting or single acting pneumatic actuator
Applicable temperature-20℃ to 150℃, confirm according to the lining material
Applicable MediumAcid alkali and compatible corrosive media

Applicable working conditions

Common features include corrosion resistance, quick cutting, optional gas loss, and can be used in chemical reactions, acid-base transportation, and environmental protection devices. When used in explosion-proof areas, actuators, limit switches, solenoid valves, or locators should be configured according to the site zoning. When used in food, pharmaceutical, or high-purity media systems, further confirmation of the contact material, surface treatment, and cleaning plan is required; Projects involving flammable, toxic, or highly corrosive media should undergo specialized safety reviews.

Installation and Debugging

Before installation, check the nameplate, flow direction, and connection standards, remove welding slag and hard debris, and avoid transmitting pipeline stress to the valve body. Maintenance space should be reserved around the actuator; If solenoid valves, limit switches, or locators are configured, their electrical interfaces should be protected according to the on-site environment; Pneumatic accessories should use a clean and dry air source that meets the requirements of the actuator. The first debugging can be carried out by checking the switch position, travel feedback, interlocking logic, and sealing of connection parts in a low-risk state, and then gradually putting them into normal operation.

Operation and maintenance

During operation, action time, valve position feedback, abnormal noise, leakage, and control signals should be recorded. When there is a delay or inability to reach the desired position, the air source, filtering and pressure reducing device, solenoid valve or positioner (if configured), limit feedback and pneumatic actuator should be checked first, and then the valve stem, valve seat and seals should be checked. Blindly increasing the driving force is not advisable. Before maintenance, it is necessary to isolate the medium, relieve pressure, and confirm that there is no residual energy; After replacing spare parts, sealing and action tests should be conducted.

Q&A on Selection of Pneumatic fluoropolymer-lined Ball Valve

What media information is required before selecting Q641F46-16C for corrosive media?

Please provide the composition, concentration, temperature, pressure, particles, and negative pressure of the medium, and check the valve body, lining, sphere, and seal item by item. Corrosion resistance does not mean that any lining material can be used or adapted to all chemical media.

When replacing the old flange ball valve with Q641F46-16C, is it enough to only check DN and PN?

It is also necessary to verify the flange standard, sealing surface, structural length, valve body and seat materials, as well as the allowable pressure at operating temperature. The installation space and connection bracket of the actuator should also be confirmed together with the site.

Q641F46-16C needs to be turned off after gas interruption. How should the actuator be configured?

The safety position required for the process in case of gas loss should be clarified first, and then the single or double acting scheme, output force or torque, and accessory circuit should be checked. You cannot select cylinders based solely on valve diameter, nor can you assume that all pneumatic configurations will close when there is a loss of air.

Selection and ordering information

Suggest providing the name and composition of the medium, design and operating temperature, maximum and normal pressure, flow range, pipeline standards, operating frequency, gas source pressure, control signals, as well as requirements for accessories such as solenoid valves or positioners, fault safety locations, and environmental protection requirements. Fouten Flow Control (Jiangsu) Co., Ltd. can be used to verify the caliber, material, seal, actuator, and accessory combination, retaining technical basis for installation and maintenance.

The selection of fluorine lining materials can be referred toPFA, FEP, and PTFE lining material selection instructionsCorresponding to electric products, please refer toQ941F46-16C electric fluoropolymer-lined ball valveSee more pneumatic ball valvesSelection of Pneumatic Ball Valve。

Online message

Provide a phone number or work email; at least one is required.

Please send drawings to the official email shown on this page. This form does not accept attachments.

Home Home Valve selectionValve selection news informationnews information Contact usContact us