Fouten Fouten Fouten
15961836110
ARC1000 automatic reflux valve minimum flow pump protection valve

ARC1000 automatic reflux valve minimum flow pump protection valve

Product Features
Automatic flow control loop
Model number
ARC1000
Specification and caliber
DN50-DN200
Pressure level
PN16
Material
WCB/304/316L
Product Introduction

The function of ARC1000 automatic reflux valve

ARC1000 automatic reflux valve, also known as automatic recirculation valve, minimum flow pump protection valve or automatic bypass valve, is mainly used in systems that require maintaining the minimum safe flow rate of centrifugal pumps. The series specifications are DN50-DN200, PN16, and material options include WCB, 304, and 316L.

Working principle

When the main flow can meet the system requirements, the bypass return flow decreases accordingly; When the main flow rate decreases, the valve increases bypass reflux through an internal mechanism, allowing some medium to return to the designated position in the system. The specific action relationship, minimum flow rate, and bypass pressure difference should be based on the actual product design and pump operating conditions calculation.

Why can't we just choose by caliber?

The automatic reflux valve is directly related to the operating conditions of the pump. In addition to the pipe diameter, it is also necessary to confirm the minimum allowable flow rate, normal flow rate, inlet and outlet pressure, bypass reflux position, and medium conditions of the pump.

Material Selection

The current parameter columns include WCB, 304, and 316L materials. The actual materials should be confirmed based on the medium, temperature, pressure, corrosiveness, and project material specifications.

For more water system products, please refer toManufacturers and Selection of Water Control ValvesFlow and pressure control can refer toElectric piston type flow and pressure regulating valve。

Frequently Asked Questions

Is the automatic reflux valve the same as a regular check valve?

Not the same. In addition to its one-way function, the automatic reflux valve also serves as a pump minimum flow protection and bypass reflux control function.

Is the bypass flow of ARC1000 fixed?

It cannot be described according to a unified fixed value, and should be confirmed based on the minimum allowable flow rate of the pump and the actual valve design.

What pump parameters are required for selection?

Suggest providing normal flow rate, minimum allowable flow rate, inlet and outlet pressure, medium, temperature, pipe diameter, and bypass reflux conditions.

Online message

Provide a phone number or work email; at least one is required.

Please send drawings to the official email shown on this page. This form does not accept attachments.

Home Home Valve selectionValve selection news informationnews information Contact usContact us