Fouten Fouten Fouten
15961836110
PYQ940F Electric Top-Entry Eccentric Ball Valve

PYQ940F Electric Top-Entry Eccentric Ball Valve

Product Features
Top-Entry Electric
Model number
PYQ940F
Specification and caliber
DN50-DN2000
Pressure level
PN16/CLASS 150/10K
Material
WCB Cast Steel/304 Stainless Steel, CF8/316L, CF8M
Product Introduction
Fouten Comprehensive Valve Selection Catalog V29 (Bilingual EN/CN)
Download PDF (143 MB)
Specification Value
Model numberPYQ940F
Specification and caliberDN50-DN2000
Pressure levelPN16/CLASS 150/10K
MaterialWCB Cast Steel/304 Stainless Steel, CF8/316L, CF8M
Product FeaturesTop-Entry Electric

PYQ940F Electric Top-Entry Eccentric Ball Valve

The PYQ940F features electric drive and a top-entry eccentric ball structure, achieving opening and closing through the eccentric movement of the ball crown relative to the valve seat. The series specifications include DN50-DN2000, as well as different standard configurations such as PN16, Class150, and 10K; the specific supply range is subject to the product technical documents and orders.

What is the function of the eccentric structure?

When the eccentric ball rotates, the ball crown contacts the valve seat at the final closing stage. For pipelines containing particles that are often idle for extended periods, the load during the first opening after sedimentation must be considered; if the process requires long-term operation at small openings, the particle scouring in the throttling area and valve seat wear should also be compared. When ordering valve seat spare parts, provide the original valve nameplate and assembly drawing to facilitate matching with the original structure.

Different pressure ratings cannot be directly equated

PN16, Class150, and JIS 10K belong to different standard systems and cannot be simply considered equivalent. When selecting, it is necessary to confirm the design standards, flange sizes, materials, and pressure-temperature ratings separately.

How to select the electric actuator?

The actuator should be selected based on the valve diameter, working pressure differential, required output torque, power supply, switching or regulation requirements, valve position feedback, and site environment. 4–20mA, communication interfaces, and explosion-proof ratings are not default configurations.

For more water system valves, see Water Control Valve Manufacturers and Selection.

How to select maintenance and drive for the electric top-entry eccentric ball valve?

The overall assembly layout should leave space for disassembly above the valve cover, maintenance space for the electric head, and emergency manual operation position. The top-entry structure cannot replace process isolation conditions, nor can it be assumed that all maintenance can be completed in situ in any installation environment.

When selecting for electric installation, also provide the maximum closing pressure differential, medium, and action frequency. If the equipment alarms on the first opening after a long stop, first check for sedimentation and starting pressure differential; if it alarms at the same turning angle each time, check for mechanical interference, drive connection, and limit. After replacement, verify the actual switch position against feedback under controlled conditions.

Frequently Asked Questions

Is the PYQ940F necessarily a regulating valve?

Not necessarily. Whether it is used for continuous regulation needs to be confirmed based on the valve structure, working conditions, and actuator configuration.

Can PN16, Class150, and 10K be directly interchangeable?

They cannot be directly interchanged solely based on grade names; it is necessary to check the flanges, materials, and pressure-temperature ratings.

Does this valve default support 4–20mA?

It does not default support; it only applies when the corresponding regulating actuator or control module is configured.

FOUTEN

Discuss your valve configuration and quotation

Provide a phone number or work email; at least one is required.

Additional service and connection details (optional)

Please send drawings to the official email shown on this page. This form does not accept attachments.