Valve selection
Explosion-Proof Electric Flanged Ball Valve BT4
| Specification | Value |
|---|---|
| Model number | FB941F |
| Specification and caliber | DN15-DN1000 |
| Pressure level | PN16/CLASS 150/10K |
| Material | WCB cast steel / 304 stainless steel, CF8 / 316L, CF8M |
| Product Features | Explosion-proof, electric ball valve |
FB941F Explosion-Proof Electric Flanged Ball Valve
The current product identity for FB941F is an explosion-proof electric flanged ball valve, marked with BT4. The valve body is operated by an electric actuator, with material configurations including WCB, CF8, and CF8M; specific materials and pressure standards are confirmed per order.
Explosion-Proof Rating Cannot Be Determined by Product Name Alone
When ordering explosion-proof electric ball valves, the hazardous area, gas group, and temperature group must be included in the technical specifications, and then verify the actuator and electromagnetic, feedback accessories' nameplates and valid certifications. BT4 and CT4 cannot be used interchangeably, nor can a single marking imply that the entire valve set has ATEX, IECEx, or other certifications.
Both Valve Body and Explosion-Proof Actuator Need Separate Confirmation
The ball valve body still needs to be selected based on the medium, temperature, pressure, flange standards, materials, and sealing; the actuator needs to confirm output torque, power supply, switching or regulating method, valve position feedback, and explosion-proof requirements.
Considerations for Hazardous Area Selection
The project should provide hazardous area classification and applicable standards, matching the certification scope of the actual actuator and accessories with on-site requirements. Electromagnetic accessories, wiring methods, and cable entries should also comply with specific project requirements.
For more electric ball valves, see Electric Ball Valve Selection.
How to Verify the Complete Delivery Documents for Explosion-Proof Electric Ball Valves?
Match the hazardous area requirements, actual models of electric heads and electrical accessories, and confirm the cable entry and wiring scheme. The explosion-proof electric assembly and valve body materials, seat, and flange requirements should be accepted separately; one marking cannot replace the entire technical conditions.
Also clarify power supply, switching or regulating, feedback, and power failure action requirements. On-site installation and maintenance should follow the project explosion-proof regulations, and do not modify electrical accessories to compensate for supply configuration omissions.
Frequently Asked Questions
Can an electric ball valve marked BT4 be used in a CT4 hazardous area?
BT4 cannot be directly considered as CT4. The actual explosion-proof markings and certification documents of the electric assembly and related accessories must be verified according to the hazardous medium, zoning, gas group, and temperature group on-site.
Do all components of an explosion-proof ball valve need explosion-proof certification?
The explosion-proof requirements mainly involve electrical equipment and accessories that may become ignition sources on-site; the specific scope should be determined according to the project explosion-proof specifications.
Does the explosion-proof electric ball valve come with default regulating functionality?
No, switching type and regulating type belong to different actuator configurations.