Fouten Fouten Fouten
15961836110
J44F Angle Type Lined Flange Gate Valve (PFA/FEP Optional)

J44F Angle Type Lined Flange Gate Valve (PFA/FEP Optional)

Product Features
Angle type, lined
Model number
J44F
Specification and caliber
DN40-DN600
Pressure level
PN16/CLASS 150
Material
Cast Steel WCB/304 (CF8) lined with PFA, FEP
Product Introduction
Fouten Comprehensive Valve Selection Catalog V29 (Bilingual EN/CN)
Download PDF (143 MB)
Specification Value
Model numberJ44F
Specification and caliberDN40-DN600
Pressure levelPN16/CLASS 150
MaterialCast Steel WCB/304 (CF8) lined with PFA, FEP
Product FeaturesAngle type, lined

The J44F angle type flange gate valve features an approximately 90° flow path arrangement, with the valve stem driving the valve disc up and down to open and close. This product is available with WCB or 304 (CF8) body configurations, and the lining material is PFA or FEP (F46). The metal valve body bears the structural pressure and flange connection, while the lining is used to isolate the corresponding liquid surface from the process medium. For corrosive media such as sulfuric acid and nitric acid, the material suitability must be determined based on concentration, temperature, pressure, and lining structure; it cannot be assumed that all corrosive media can be used just because it is called “lined with fluorine.”

Cast Steel Lined Teflon Angle Flange Gate Valve Structure Diagram

Cast Steel Lined Teflon Angle Flange Gate Valve Dimension Diagram

For special lining materials, flange connections, or installation structures, please provide details such as medium name and concentration, working temperature, pressure rating, pipe diameter, and connection dimensions to confirm the corresponding valve selection and customization requirements.



Structural Features of J44F Lined Angle Gate Valve

The J44F adopts an angle flow path structure, forming an approximately 90° arrangement for the inlet and outlet directions, which can reduce additional elbow configurations in situations where the pipeline direction needs to be changed or installation space is limited. The gate valve achieves opening and closing through the cooperation of the valve disc and valve seat, with specific flow direction and installation method to be based on product identification and drawings.

Role of PFA and FEP Linings

The product's flow area uses PFA or FEP and other fluorinated materials for lining, isolating corrosive media from the metal valve body. PFA and FEP (F46) are different fluorinated polymers, and the specific choice needs to be confirmed based on medium name, concentration, temperature, pressure, and lining structure.

The valve's suitability for all acids, bases, or solvents cannot be determined solely based on the name “lined with fluorine,” nor should a uniform maximum working temperature be applied to PFA/FEP.

How to Choose Valve Body Material?

The current product valve body can be selected from WCB or 304 (CF8) options. Since the working medium is primarily isolated by the lining and the metal substrate, the valve body material still needs to be chosen based on external environment, mechanical strength, temperature, pressure, and project material requirements.

What Parameters Need to be Confirmed for Selection and Installation?

In addition to the J44F model, confirm DN, PN or Class pressure rating, flange standards, medium, concentration, temperature, PFA or FEP lining requirements, valve body material, and opening and closing frequency. For strong vacuum, negative pressure, media containing particles, or severe temperature fluctuations, the lining structure and valve applicability should be verified separately.

Common Questions about J44F Lined Gate Valve

Why does J44F use a 90° angle flow path?

The angle structure allows for approximately 90° changes in the direction of the medium's inlet and outlet, suitable for situations where the pipeline direction needs to be changed or where reducing the installation of independent elbows is desired; specific installation dimensions should be based on product drawings.

Can PFA and FEP linings be interchanged freely?

They cannot be simply interchanged. Both are fluorinated materials, but their material and processing characteristics differ, and should be determined based on medium, temperature, pressure, and actual lining process.

Can the J44F lined gate valve be used in vacuum or negative pressure conditions?

It cannot be judged solely based on the lining name. Negative pressure or vacuum may impose additional requirements on lining fixation and stability, which need to be confirmed based on specific product structure and working conditions.

FOUTEN

Discuss your valve configuration and quotation

Provide a phone number or work email; at least one is required.

Additional service and connection details (optional)

Please send drawings to the official email shown on this page. This form does not accept attachments.

Home Home Valve selectionValve selection news informationnews information Contact usContact us