Should I specify PFA, FEP or PTFE for my acid service?
Provide the full chemical mixture and concentration, impurities, normal and maximum temperatures, pressure and cleaning conditions. PFA, FEP and PTFE are different fluoropolymers, not interchangeable names for one lining. Check chemical compatibility and the complete valve's pressure-temperature limits for the specified construction; a resin property alone does not establish the valve rating.