Pneumatic flange ball valve Q641F-16P

Pneumatic flange ball valve Q641F-16P

Product Features
Quick cut-off, flange connection, and optional gas loss position
Model number
Q641F-16P
Specification and caliber
DN15-DN200
Pressure level
PN16
Material
CF8/CF8M
Product Introduction

Pneumatic Flange Ball Valve Q641F-16P Product Description

Pneumatic flange ball valve Q641F-16P is designed for automatic switching or process control needs in chemical pipelines, water treatment, food utilities, and equipment interlocking. When selecting, one should start from the actual working conditions, check the medium name, temperature, maximum and normal flow rates, pressure before and after the valve, connection standards and control methods, and not simply copy the valve diameter based on the existing diameter. The parameters provided in this article belong to the commonly used configuration range, and the final execution data should be based on the project operating conditions, order confirmation form, and manufacturing drawings.

Product Specifications

Product ModelQ641F-16P
Structural formTwo piece straight channel, flange connection, floating ball structure
Nominal DiameterDN15-DN200
pressure ratingPN16
Valve body materialCF8/CF8M
sealing formPTFE or enhanced PTFE soft seal
Drive TypeDouble acting or single acting pneumatic actuator
Applicable temperature-20℃ to 180℃, confirm according to the sealing material
Applicable MediumWater, air, oil and compatible process media

Structure and working mode

Q641F-16P adopts a two-piece straight channel, flange connection, and floating ball structure, which is driven by a pneumatic actuator to rotate the ball and complete the opening, closing, and cutting of the pipeline. The actuator is selected based on the valve operating torque, maximum working pressure difference, and available air source pressure, and the thrust indicator of a straight stroke valve cannot be directly used as the output requirement of this valve. Single acting or double acting configurations, air loss positions, as well as accessories such as solenoid valves and limit feedback, should be matched with the control scheme. Continuous adjustment requires verification of the ball flow channel, valve seat, and positioning control conditions.

Caliber pressure and material selection

The commonly used caliber is DN15-DN200, and the pressure rating is PN16. The valve body material can be selected as CF8/CF8M, but the material selection cannot be separated from the corrosiveness of the medium, chloride ion content, temperature fluctuations, and cleaning conditions. PTFE or enhanced PTFE soft seal, its allowable temperature, pressure difference, and leakage level need to be checked simultaneously. For steam, crystallization prone, particle containing, or frequent operating conditions, further confirmation should be made on the hardness of valve internals, packing form, and erosion prevention measures.

Product features and applicable industries

The main features of this product are quick cutting, flange connection, and optional loss of air position. After reasonable configuration, it can be used for chemical pipelines, water treatment, food utilities, and equipment interlocking. When used in hazardous areas, the corresponding actuator, solenoid valve, limit switch or locator should be selected according to the explosion-proof zone on site; When used in food, pharmaceutical and other systems, it is also necessary to confirm the requirements for liquid handling materials, surface treatment and cleaning. Any project involving oxygen, strong corrosive or toxic media should undergo specialized material and safety reviews.

Installation and Debugging

Before installation, check the nameplate, specified flow direction, flange standard, and sealing surface, remove welding slag and hard debris inside the pipe, ensure that the pipeline is aligned with the valve, and avoid applying additional stress to the valve body. Maintenance space should be reserved around the actuator; The quality and pressure of the gas source should meet the requirements of the supporting actuator and accessories, and the configured electrical accessories should be properly wired for protection. During debugging, check the opening and closing direction, valve position feedback, and air loss action, and complete the sealing, action, and interlocking tests according to regulations.

operation and maintenance

During operation, the action time, abnormal noise, leakage, valve position feedback, and control signals should be observed. If the action is slow, first check the air source, filter pressure reducing device, solenoid valve or positioner (if configured), valve position feedback and pneumatic actuator, and then check the valve stem, valve seat and seals. It is not advisable to blindly increase the driving force. Before maintenance, it is necessary to isolate the medium, relieve pressure, and confirm that the equipment has no residual energy. After replacing the seal, strength, sealing, and action tests should be conducted according to regulations, and the material of the spare parts and the date of maintenance should be recorded.

Corresponding electric products can be found inQ941F-16P electric flange ball valveFor more pneumatic products, please refer toSelection of Pneumatic Ball Valve。

Q641F-16P Pneumatic Flange Ball Valve Common Problems

Can Q641F-16P be directly used as a continuous control valve?

It cannot be judged solely based on pneumatic drive. Ordinary straight through ball valves are mainly used for opening, closing, and cutting.

How to determine the position of gas loss for a single acting actuator?

The design scheme of gas loss opening, gas loss closing or other measures should be determined according to the process safety requirements, and clearly stated when ordering.

Is CF8M necessarily suitable for all corrosive media?

No, it needs to be judged based on the specific composition, concentration, temperature, and material compatibility of the medium.

Order Information List

Suggest providing the composition of the medium, design and operating temperature, maximum and normal pressure, flow range, pipeline standards, operating frequency, control signals, power or gas supply conditions, fail safe location, and environmental protection requirements. Fouten Flow Control (Jiangsu) Co., Ltd. will verify the valve diameter, material, seal, actuator, and accessory combination based on these materials to ensure that the product parameters are consistent with the actual pipeline conditions, and provide traceable basis for subsequent installation and maintenance.

Online message

Provide a phone number or work email; at least one is required.

Please send drawings to the official email shown on this page. This form does not accept attachments.

Home Home Valve selectionValve selection news informationnews information Contact usContact us