Fouten Fouten Fouten
15961836110
Pneumatic three-way ball valve Q614F-16P

Pneumatic three-way ball valve Q614F-16P

Product Features
Three way diversion and merging, threaded connection, quick action
Model number
Q614F-16P
Specification and caliber
DN15-DN50
Pressure level
PN16/PN25
Material
CF8/CF8M
Product Introduction

Pneumatic three-way ball valve Q614F-16P

The Q614F-16P pneumatic three-way ball valve uses a T-port ball and threaded connections to switch, divide or combine compatible process routes. The actuator rotates the ball into defined positions, bringing the required ports into communication. Equipment feed, return and bypass connections are selected together with the operating positions.

Product Specifications

Product ModelQ614F-16P
Structural formT type three-way flow channel, internal thread connection, floating ball structure
Nominal DiameterDN15-DN50
pressure ratingPN16/PN25
Valve body materialCF8/CF8M
sealing formPTFE Soft Seal
Drive TypeDouble acting or single acting pneumatic actuator
Applicable temperature-20℃ to 180℃, confirm according to the sealing material
Applicable MediumWater, air, oil and compatible media

How the valve moves and seals

The internal T-port moves relative to the three body ports as the ball turns. Ball orientation, pipe connections and actuator stops determine the actual route. Unequal branch pressures and temporary overlap during movement can cause mixing or reverse flow, so the transition is considered alongside the two end positions.

Body and sealing materials

CF8 or CF8M body options carry line pressure; the ball, stem, PTFE seats and auxiliary seals perform separate fluid-contact and sealing tasks. Include cleaning fluids as well as the normal product when choosing materials. Temperature and differential pressure also affect seat contact and operating torque.

Operating conditions

For equipment switching between feed and return, first compare the routes at each end position, then examine the path during rotation. A duty permitting brief overlap can use a different arrangement from a duty requiring separation throughout movement. Feedback is assigned to the actual process route.

Installation and commissioning

Match the thread system and sealing method to the mating pipework, supporting the connection while tightening. Air-line capacity, solenoid passages and exhaust restriction affect switching speed. Under safely isolated conditions, verify each port route against the actuator position and feedback before process commissioning.

Inspection and maintenance

When movement slows, compare pressure during the stroke, travel time in both directions and actual stem movement. Flow through an unwanted route at the final position calls for a separate check of ball alignment, trapped material and seat condition. Isolate and depressurize before opening the valve or disconnecting stored-energy components.

For more pneumatic products, please refer toSelection of Pneumatic Ball ValveThe electric T three-way structure can be referred toQ945F-16P electric three-way ball valve。

Q614F-16P Pneumatic Three way Ball Valve Common Problems

Why do two fluids mix briefly during switching?

The ball port may connect the branches for part of its rotation. Compare the transition path with the final positions. Continued mixing at a final position also calls for checks of alignment and seat condition; a separation-critical process needs an appropriate isolation arrangement.

The position lamp is correct, but the fluid goes to the wrong branch. What should I check?

Compare port numbering, ball orientation and the mechanical connection to the actuator. A position switch detects its sampling point, while the actual fluid route depends on the complete valve assembly. Check these relationships under safe isolation.

How can the valve return to the recirculation route after air failure?

Select the spring direction and air circuit for that actual ball position, and check available return torque against the operating load. Feedback and upstream equipment interlocks should correspond to the same return route.

Ordering information

Provide numbered ports, the route at each operating position and whether overlap is permitted during movement. Add fluid, temperature, pressure, cycle frequency and air-supply conditions. Solenoid voltage, feedback and failure position are selected for the control task; replacement work also needs thread and installation dimensions.

FOUTEN

Discuss your valve configuration and quotation

Provide a phone number or work email; at least one is required.

Additional service and connection details (optional)

Please send drawings to the official email shown on this page. This form does not accept attachments.

Home Home Valve selectionValve selection news informationnews information Contact usContact us