Pneumatic fluoropolymer-lined butterfly valve D671F46-16C

Pneumatic fluoropolymer-lined butterfly valve D671F46-16C

Product Features
Corrosion resistance, clamp installation, pneumatic quick cutting
Model number
D671F46-16C
Specification and caliber
DN50-DN300
Pressure level
PN10/PN16
Material
WCB fluorine lining
Product Introduction

Pneumatic fluoropolymer-lined butterfly valve D671F46-16C Product Description

Pneumatic fluoropolymer-lined butterfly valve D671F46-16C is suitable for automatic switching, switching or process control conditions in chemical, environmental protection, surface treatment and wastewater treatment systems. Before determining the configuration, a comprehensive judgment should be made based on the composition of the medium, operating temperature, maximum and normal flow rates, pressure before and after the valve, connection standards, operating frequency, and control signals. The model cannot be directly determined based solely on the existing pipe diameter. The following parameters are commonly used configuration ranges, and actual supply should be based on project conditions, technical confirmation forms, and manufacturing drawings.

Product Specifications

Product ModelD671F46-16C
Structural formClamp connection, PTFE lining, soft seal butterfly plate
Nominal DiameterDN50-DN300
pressure ratingPN10/PN16
Valve body materialWCB fluorine lining
sealing formPTFE lining soft seal
Drive TypeDouble acting or single acting pneumatic actuator
Applicable temperature-20℃ to 150℃, confirm according to the lining material
Applicable MediumAcid alkali, salt solution, and compatible corrosive media

Structure and working mode

D671F46-16C adopts clamp connection, PTFE lining, and soft sealed butterfly plate. During operation, the opening and closing components are driven by a double acting or single acting pneumatic actuator to change the flow cross-section, achieving cutting, reversing, or adjustment. The actuator should be selected according to the maximum pressure difference, valve stem thrust or output torque, and a reasonable margin should be reserved. When remote feedback, proportional adjustment, or interlocking is required, the control signal, power or gas supply conditions, protection level, action time, and fault safety position should be clearly defined during the ordering stage to avoid inconsistencies between accessory interfaces and on-site control logic.

Caliber pressure and material selection

The commonly used nominal diameter is DN50-DN300, and the pressure rating is PN10/PN16. The valve body material can be selected as WCB fluorine lining, and its adaptability needs to be confirmed in combination with the corrosiveness of the medium, temperature cycling, particle content, and external environment. The allowable temperature, pressure difference, and leakage requirements for the PTFE lining soft seal should be checked synchronously. For pipelines that are prone to crystallization, contain particles, frequently move, or have significant temperature changes, the wear resistance of valve internals, packing structure, support method, and erosion prevention measures should also be confirmed.

Product features and applicable industries

The main features of this product include corrosion resistance, clamp installation, and pneumatic quick cutting. After reasonable configuration, it can be used in chemical, environmental protection, surface treatment, and wastewater treatment systems. When dealing with flammable, explosive, highly corrosive, high-temperature, or toxic media, explosion-proof actuators, locators, solenoid valves, limit switches, and corresponding materials should be selected according to site specifications, and general parameters should not replace special safety reviews.

Installation and Debugging

Before installation, the nameplate, flow direction, connection standard, and sealing surface should be checked, welding slag and hard debris in the pipeline should be removed, and the front and rear pipe sections should be ensured to be concentric. It is forbidden to use valves to forcibly correct pipeline deviations. Maintenance space should be reserved around the actuator, cable entrances should be protected from rainwater backflow, and pneumatic accessories should use clean and dry air sources. The first debugging should be carried out under low-risk conditions to check the fully open and fully closed positions, travel feedback, interlocking logic, sealing condition, and abnormal noise, and then gradually increase to the working pressure.

operation and maintenance

During operation, action time, valve position feedback, leakage, pressure difference, and control signals should be recorded. If the action is slow or the switching is not in place, the power or gas source, wiring, filter pressure reducing valve, locator, and actuator should be checked first, and then the valve stem, valve seat, and seals should be checked. Blindly increasing the driving force is not advisable. Before maintenance, it is necessary to isolate the medium, relieve pressure, and confirm that there is no residual energy; After replacing the seals, conduct strength, sealing, and action tests according to regulations, and keep records of spare parts materials and maintenance.

Q&A on Selection of Pneumatic fluoropolymer-lined Butterfly Valve

D671F46-16C is used for acid-base solutions. Which materials need to be confirmed first?

Please provide the name, concentration, temperature, pressure, and particle and negative pressure of the medium, and verify the valve body, liquid receiving lining, valve seat, and seal separately. It is not enough to determine that all acidic and alkaline solutions are suitable based solely on the corrosion resistance name, and material options cannot be replaced without verification.

Can D671F46-16C directly replace the original flange butterfly valve?

Please provide the connection standard, structural length, sealing surface, and on-site space of the old valve, and verify the driving height and flow direction requirements of the new valve. It cannot be determined that direct replacement can be made solely based on the same caliber and nominal pressure.

D671F46-16C needs to be turned off after gas interruption. How should the actuator be configured?

The safety position required for the process in case of gas loss should be clarified first, and then the single or double acting scheme, output force or torque, and accessory circuit should be checked. You cannot select cylinders based solely on valve diameter, nor can you assume that all pneumatic configurations will close when there is a loss of air.

Order Information List

Suggest providing the composition of the medium, design and operating temperature, maximum and normal pressure, flow range, pipeline standards, operating frequency, control signals, power or gas supply conditions, fail safe location, and environmental protection requirements. Fouten Flow Control (Jiangsu) Co., Ltd. will verify the caliber, material, seal, actuator, and accessory combination based on these materials to ensure that the product parameters are consistent with the actual pipeline conditions, and provide traceable basis for subsequent installation and maintenance.

Online message

Provide a phone number or work email; at least one is required.

Please send drawings to the official email shown on this page. This form does not accept attachments.

Home Home Valve selectionValve selection news informationnews information Contact usContact us