Fouten Fouten Fouten
15961836110
Pneumatic Clamp Valve G641J-6L

Pneumatic Clamp Valve G641J-6L

Product Features
Sleeve liquid contact, control air pressure and medium pressure coordination, particle and flow stop maintenance
Model number
G641J-6L
Specification and caliber
DN25-DN100, interfaces and casing specifications to be verified against selected series
Pressure level
PN6
Material
Aluminum alloy shell
Product Introduction
Fouten Comprehensive Valve Selection Catalog V29 (Bilingual EN/CN)
Download PDF (143 MB)
Specification Value
Model numberG641J-6L
Specification and caliberDN25-DN100, interfaces and casing specifications to be verified against selected series
Pressure levelPN6
MaterialAluminum alloy shell
Product FeaturesSleeve liquid contact, control air pressure and medium pressure coordination, particle and flow stop maintenance

G641J-6L pneumatic clamp valve uses an elastic sleeve as the liquid contact and closing component, suitable for cutting off matched materials such as particles, fibers, or slurries. The reference structure directly acts on the outer side of the sleeve with compressed air from the housing interface, rather than using an additional double-acting cylinder to drive a mechanical clamp rod.

Product Parameters

ModelG641J-6L
Structure TypePressure-driven elastic sleeve cut-off structure
Nominal DiameterDN25-DN100, interface and sleeve specifications to be verified according to selected series
Pressure RatingPN6
Body MaterialAluminum alloy shell
Sealing TypeNatural rubber or wear-resistant elastic sleeve
Actuation MethodCompressed air directly acting on the outer side of the sleeve, completing actions through intake and exhaust
Applicable TemperatureDetermined by sleeve material, medium, and manufacturing temperature and pressure data
Applicable MediumPowders, particles, slurries, and solid-containing fluids

Distinguishing Direct Pressure Type from Cylinder Clamp Rod Type

The direct pressure type feeds control air into the housing, compressing the sleeve inward to form a cut-off; the cylinder clamp rod type compresses the sleeve through an external mechanism. The air paths, fault positions, and maintenance targets of the two types differ and should not be mixed.

Inquiry and piping diagrams specify structure, control interfaces, and sleeve numbers; do not replicate the gas supply or reset logic of another type of clamp valve on-site.

Medium Primarily Contacts the Sleeve, Material Must Be Specifically Selected

The shell material cannot replace the verification of the sleeve's compatibility with the medium. Provide acid-base components, concentration, temperature, particle hardness, and cleaning agents to confirm the sleeve and end seals separately.

Wear-resistant formulations, food contact requirements, and chemical compatibility are different conditions; simply stating one rubber name does not imply all are satisfied; spare parts should clearly specify material, size, and applicable medium.

Control Pressure Must Be Considered Along with Pipeline Pressure

Cut-off requires establishing an appropriate pressure relationship between the outer side of the sleeve and the medium side; actual allowable conditions are determined according to the selected valve and sleeve data. When actions are slow, compare the dynamic air pressure at the control inlet with the medium pressure, checking the regulator, joints, and gas supply diameter.

Do not treat the control pressure differential values of other products as universal settings, nor continuously increase air pressure against unknown blockages.

Particles Can Pass Does Not Mean Any Material Is Applicable

Record particle size, solid content, fibers, and the presence of sharp particles. Repeated bending of the sleeve and particle friction can cause fatigue and wear, and material clamping during closure may also affect lifespan.

Media that crystallize or solidify after flow stoppage require reasonable emptying and cleaning procedures; the valve does not have a traditional metal valve chamber, which does not mean the entire pipeline will not accumulate or block.

Negative Pressure and Loss of Gas State Require Separate Confirmation

The sleeve of the direct pressure clamp structure may be affected by the pressure differential inside and outside the pipe and should not be used for vacuum or negative pressure sections without confirmation. The position after loss of gas is also affected by sleeve elasticity, medium pressure, and gas path status; when a safe cut-off is required, it must be designed and verified according to specific plans.

Include pump inlet, shutdown, and reverse pressure conditions in the data sheet, not just report normal positive pressure.

Protect Sleeve and Control Interface During Installation

Verify end connections, effective inner diameter, and support to avoid misalignment of piping or installation torque damaging the sleeve ends. Control air must connect to the specified interface on the housing; medium interfaces and gas paths must not be mixed.

Check for external leaks, switches, and exhaust according to approved procedures, recording action times and actual cut-off conditions; surface contact does not replace seal acceptance, and hard tools should not be used to damage the inner wall.

Check Lifespan by Observing Action Records and Sleeve Condition

Routine inspections should focus on external leaks, abnormal air consumption, changes in closing time, and medium-side leaks. If sleeve cracks, localized wear, or repeated failure to close tightly are found, isolate the medium, relieve control air pressure, and replace according to procedures.

Before disassembly, confirm that there is no residual pressure in the housing and pipeline; after reassembly, verify sleeve positioning and end seals. Maintenance cycles should be determined based on action counts, materials, and inspection results.

Common Questions for Procurement and On-Site Use

Why Does This Clamp Valve Not Have an External Cylinder?

The direct pressure type applies pressure to the outer side of the sleeve from the housing interface, utilizing sleeve deformation for cut-off. It differs from the cylinder clamp rod type and should configure gas paths and maintenance according to direct pressure structure.

Is the Aluminum Alloy Shell Corrosion-Resistant Enough for Acid-Base Liquids?

Carefully verify the actual liquid-contact sleeve, end seals, and risks after abnormal leaks. Concentration, temperature, and cleaning conditions must be provided; do not judge solely based on the shell or medium name.

If It Doesn't Seal Well, Can I Just Increase the Control Air Pressure?

First, compare the medium pressure with the specified control conditions, then check the gas path, material clamping, and sleeve damage. Exceeding the allowable control pressure may damage the sleeve; do not use continuous pressurization as a substitute for inspection.

What Information Is Needed When Ordering?

Provide particle characteristics, pressure variations, temperature, sleeve compatibility requirements, connection sizes, and allowable action times when ordering. If vacuum or reliable fault positions are needed, state them separately; matching sleeve and gas path data should be delivered with the goods.

For more similar structures, see the pneumatic valve section, using the same working conditions and acceptance requirements for comparison.

Images are for reference of shape and drive structure, not for proving specific materials, pressure ratings, or internal valve cores; actual configurations should be verified against confirmed supply drawings.

FOUTEN

Discuss your valve configuration and quotation

Provide a phone number or work email; at least one is required.

Additional service and connection details (optional)

Please send drawings to the official email shown on this page. This form does not accept attachments.

Home Home Valve selectionValve selection news informationnews information Contact usContact us