Valve selection
Pneumatic Three-Way Flanged Ball Valve
| Specification | Value |
|---|---|
| Model number | Q645F |
| Specification and caliber | DN25-DN800 |
| Pressure level | PN16/CLASS 150/10K |
| Material | WCB Cast Steel / 304 Stainless Steel / 316L |
| Product Features | Three-way, Pneumatic |
Pneumatic Three-Way Flanged Ball Valve Q645F
The Q645F features a pneumatic actuator and a three-way flanged ball valve structure, with sizes ranging from DN25 to DN800. The pressure ratings include PN16, Class150, and 10K, and materials include WCB, 304, and 316L.
How to Switch Flow Paths Between L-Type and T-Type
The L-type ball core connects the common port with one branch through adjacent passages, suitable for switching between two routes. The T-type can form more interconnected combinations for corresponding diverging, converging, or bypass tasks. The opening of the ball core, assembly direction, and actuator stop position together determine the actual passage for each position.
How to Pipe PN, Class, and JIS Connections
PN16, Class150, and JIS 10K respectively follow their standard systems for flange dimensions and pressure-temperature rating rules. When replacing old components, compare the hole spacing, hole diameter, sealing surface, and face-to-face dimensions of the paired flanges on the same size chart, and then determine the pressure rating based on the selected materials and temperature.
How to Match Pneumatic Action with Fault Positions
The cylinder converts supply pressure into angular stroke output, the solenoid valve changes the supply and exhaust routes, and limit switches or positioners provide corresponding position functions. The double-acting scheme relies on air routes on both sides for driving, while the spring return scheme relies on springs to complete the specified directional movement when the air supply fails; during selection, compare the siteâs minimum dynamic air pressure and full stroke load.
For Class150 specialized products, see Pneumatic Three-Way American Standard Ball Valve (Q645F); for more pneumatic ball valves, see Pneumatic Ball Valve Selection.
How Does the Switching Process Affect Branch Mixing?
For example, if the common port needs to switch between feed and return, both endpoints must be correct, but rotating to the middle position may still temporarily connect the two branches. If the process allows for short-term mixing, arrangements can be made according to the corresponding openings and stop positions; if strict separation is required, isolation and interlocking schemes need to be compared.
Number the three interfaces on the flow direction diagram and list the passages for each position and switching process. Control commands and position feedback must correspond to these actual flow paths to ensure that the upstream pump, downstream equipment, and valve actions are in sequence.
Frequently Asked Questions
Should I use L-type or T-type for a single feed pipe to two tanks?
First, number the common port and the two discharge branches. If only one of the two routes is to be selected, the L-type scheme can be compared; if both branches need to be connected simultaneously or more combinations are required, then compare the T-type openings and stop positions. Whether short-term connection between the two tanks is allowed during switching should also be considered in the selection.
The air source pressure gauge is normal, but the three-way ball valve switches slowly. What should I check?
When the static pressure is normal, the action may still slow down due to supply capacity or exhaust resistance. By comparing the cylinder inlet pressure, timing in both directions, and exhaust state during action, one can distinguish between insufficient supply, restricted accessory passages, and increased load within the valve.
How to configure if I want to switch from feed to return pipe after stopping the air supply?
Determine the actual ball core position, rotation direction, and spring return direction corresponding to the return, while also comparing the load within the return stroke. Position feedback corresponds to the final flow path, and upstream feed equipment should also adopt the corresponding interlocking sequence.