Valve selection
ANSI Class600 Swing Check Valve
| Specification | Value |
|---|---|
| Model number | H44H-600LB |
| Specification and caliber | 1”-36” |
| Pressure level | CLASS 600# |
| Material | Cast Steel WCB/304 (CF8) /316L |
| Product Features | American Standard Class 600LB |
Class600 Swing Check Valve Structure
H44H-600LB Class600 American Standard swing check valve features flanged connection and swing disc structure. When the medium flows in the forward direction, it pushes the disc open; when the flow decreases or a reverse flow trend occurs, the disc falls back and restricts backflow of the medium.
Class600 Cannot Be Directly Understood as a Fixed Pressure Value
Class 600 is a grade designation in the American standard pressure rating system and does not represent the same fixed allowable working pressure under all material and temperature conditions. The actual pressure-temperature rating needs to be confirmed based on the valve body material, design temperature, and specific standards adopted for the project.
How to Choose Materials?
The valve body can be selected from materials such as WCB, CF8, or 316L according to the corresponding product configuration, and the casting and forged materials should be specified with their material standards. First, select the wetted materials based on the medium, concentration, and temperature, then verify the pressure-bearing capacity of that material at the design temperature, and do not consider Class600 as a fixed working pressure common to all configurations.
What Needs to Be Confirmed About Flanges and Installation?
During selection, it is necessary to confirm the nominal size, Class rating, flange standard, sealing surface, structural length, medium flow direction, and installation space. Products from different standard systems or different pressure ratings cannot be directly replaced based solely on nominal diameter.
For more products, you can check check valve manufacturers and check valve selection; for lower pressure rating American standard swing structures, refer to American Standard Swing Check Valve.
Frequently Asked Questions
Is Class600 a fixed 600PSI?
No. Class 600 is a pressure grade name, and the actual allowable pressure needs to be confirmed based on materials, design temperature, and pressure-temperature ratings in applicable standards.
Can WCB and CF8 be directly interchanged?
No, they cannot be directly interchanged based solely on size. They belong to different material systems and should be determined based on the corrosiveness of the medium, temperature, pressure, and project material requirements.
Does a swing check valve require an electric actuator?
Typically, it does not. A swing check valve mainly relies on the flow of the medium and pressure difference for automatic opening and closing, and the actual closing characteristics are also related to flow rate, disc structure, and installation conditions.

news information