Fouten Fouten Fouten
15961836110
JIS20K Japanese Standard Lift Check Valve SCS13 SCS14

JIS20K Japanese Standard Lift Check Valve SCS13 SCS14

Product Features
With bypass, slow closing
Model number
DZH42X
Specification and caliber
50A-600A
Pressure level
JIS 10K/20K
Material
SCPH2/SCS13/SCS14
Product Introduction
Fouten Comprehensive Valve Selection Catalog V29 (Bilingual EN/CN)
Download PDF (143 MB)
Specification Value
Model numberDZH42X
Specification and caliber50A-600A
Pressure levelJIS 10K/20K
MaterialSCPH2/SCS13/SCS14
Product FeaturesWith bypass, slow closing

JIS20K Lift Check Valve

DZH42X JIS20K lift check valve adopts a lift disc structure, with series documentation indicating bypass and slow closing functions. The valve disc opens during forward flow of the medium, and closes when flow decreases or a reverse flow trend occurs, to reduce backflow of the medium.

Bypass and Slow Closing Functions Need to Be Confirmed Based on Actual Structure

When bypass or slow closing functions are required, the actual channels, actuating mechanisms, and adjustment methods should be verified in the product drawings, and coordinated with the pipeline shutdown process. The term 'slow closing' itself does not indicate the use of hydraulic cylinders or any specific damping device, nor does it prove that there are no impacts under all working conditions.

JIS20K Cannot Be Directly Equated to PN40 or Class300

JIS 20K belongs to the Japanese pressure rating system. The pressure-temperature rating rules, material groups, and flange sizes differ across various standard systems, so JIS20K cannot be directly equated to PN40, Class300, or any fixed MPa value.

Material Selection

The series documentation lists materials SCPH2, SCS13, and SCS14. Specific materials should be confirmed based on the medium, design temperature, pressure, corrosiveness, and project material requirements.

For standard JIS10K lift structures, refer to Japanese Standard Lift Check Valve; for more products, see Check Valve Manufacturers and Selection.

What Pipeline Conditions Are Required for Lift Check Valves at Pump Outlets?

The installation direction, normal and low flow conditions, pump shutdown process, backflow risks, and adjacent pipe fittings should be specified to confirm the conditions for valve disc movement. Selection cannot be based solely on the pump outlet diameter or Japanese standard ratings.

If the project requires slow closing, bypass, or specific water hammer performance, these should be listed separately in the technical specifications and verified. The lift check structure itself does not prove that these functions are configured; on-site installation should be marked according to the actual flow direction.

Frequently Asked Questions

Is JIS20K equal to PN40?

They cannot be directly equated. Pressure-temperature ratings should be verified based on the specific JIS standards, materials, and design temperatures.

Does slow closing necessarily use hydraulic damping?

This cannot be assumed. The specific slow closing mechanism needs to be checked in the actual product structure drawings or technical documentation.

Do all sizes with bypass use the same structure?

This cannot be generalized. The bypass structure, dimensions, and configurations should be based on the specific model and order technical documents.

FOUTEN

Discuss your valve configuration and quotation

Provide a phone number or work email; at least one is required.

Additional service and connection details (optional)

Please send drawings to the official email shown on this page. This form does not accept attachments.

Home Home Valve selectionValve selection news informationnews information Contact usContact us